Showing posts with label Time Step Critical Elements in SWMM 5. Show all posts
Showing posts with label Time Step Critical Elements in SWMM 5. Show all posts

Sunday, December 26, 2010

Time Step Critical Elements in SWMM 5

Subject: Time Step Critical Elements in SWMM 5

The time step critical elements in the SWMM 5 report text output file tells you which elements were controlling the time step during the simulation. If no element was controlling the time step then the program will just use the maximum time step. For example, if the maximum time step was 10 seconds and the average time step was 9.8 then only a few time steps were set by a link or node that needed a smaller than maximum time step (Figure 1). If the maximum time step for the same simulation was 30 seconds then many links and nodes will set the time step (Figure 2).

Figure 1. Most of the time the simulation used the maximum time step of 10 seconds so only a few links were time step critical.
Figure 2. Most of the time the simulation used less than the maximum time step of 30 seconds so many links were time step critical.

The Goal of SWMM5 Input Files

 ðŸŒŸ SWMM5 (Storm Water Management Model 5) is a widely used urban hydrology and hydraulic modeling software developed by the United States E...