Subject:   Storage Nodes in InfoSWMM and H2OMAP SWMM

Figure 1 shows how to use the various constants, coefficients and exponents in the Storage or Wet Well data of H2OMAP SWMM.     If you have a Wet Well or Storage Diameter you should convert the Wet Well diameters into an Area with the units of either square feet or square meters.  The computed area will then be a constant or coefficient in the Attribute Browser.  You would only use the exponent or a table of depth and area if the Wet Well area varies with depth. 
Figure 1.  Options for Defining a Storage Node in H2OMAP SWMM or SWMM 5





No comments:

RTK SWMM5 Import to ICM using ODIC

  Object Fields Import Fields Default Values RTK hydrograph ID ID Response ratio R - short term RFVOL_EFF 0.050 Time to peak T - short term ...