Sunday, August 4, 2013

Pump Volume per Pump Event in SWMM 5

Subject: Pump Volume per Pump Event in SWMM 5

You can calculate the volume per startup event by using the Pump Summary Table in SWMM 5 and copying a few columns to Excel.   


1.   Go to the Pump Summary
2.   Copy Pump Name, Total Volume and Pump Startups to Excel
3.   Divide to get Pump Volume per Event

You will now have the average volume per event.


Pump
Total
Total Volume
Pump
Name
Volume (ML)
Per Event
Startups
PUMP-11
0.006082
202.73
30
PUMP-13
0.005539
184.63
30
PUMP-15
0.006241
208.03
30
PUMP-17
0.0064
213.33
30
PUMP-19
0.005405
180.17
30
PUMP-21
0.006199
206.63
30
Inc.